ABT, Inc. • PO Box 837 • 259 Murdock Road • Troutman, NC 28166
(800) 438-6057 • (704) 528-9806 • Fax: (704) 528-5478
> PolyDrain > Installation > Catch Basin Installation
Catch Basin Installation
- Locate positions for catch basins and excavate. Remember, the depth of the bedding concrete must be equivalent to the slab thickness but not less than 4".
- Determine which preformed cutouts are to be used and remove prior to placing catch basin in position.
- Pour bedding concrete and set catch basin on top as soon as concrete is stiff enough to support it. Set catch basin to proper grade and alignment using stringline or level.
- Install pipe connections.
- Backfill with concrete around the sides of the catch basin up to the channel excavation level.
![]() |
![]() |
![]() |
![]() |
© 1998–2008 — ABT, Inc.